Arrhythmias & electrophysiologyCohort study

Cardiac implantable electronic device implantation and device-related infection

EuropacePublished

  • Retrospective cohort study
  • National Inpatient Sample database 2011–2018

Authors' conclusion

Device-related infection is relatively common and continues to be associated with high morbidity and mortality. The prevalence of DRI has not changed significantly despite technical and technological advances in cardiac devices and their implantation.

Study context

Population
Admissions for cardiac implantable electronic devices (CIED) implantation and device-related infection, US National Inpatient Sample, 2011–2018
Participants
1,604,173 CIED implantation admissions
Exposure
Device-related infections (DRI) vs no DRI among CIED admissions
  • DRIn = 71,007
  • CIED implantationn = 1,604,173reference
Outcome
Trend in CIED implantations and burden and morbidity of DRI

Main finding

As reported in the abstract

DRI admission rate

DRI

4.4%

71 007 of 71 007

No significant change in annual DRI admission rates (3.96-4.59%)
P for trend = 0.98

Observational data: associations, not effects.

Further findings

OutcomeOR (95% CI)P value
Predictors of in-hospital mortality with DRI (multivariate) — CHF vs CIED implantation1.67 (1.35–2.07)
Predictors of in-hospital mortality with DRI (multivariate) — End-stage renal disease vs CIED implantation1.90 (1.46–2.48)
Predictors of in-hospital mortality with DRI (multivariate) — Coagulopathy vs CIED implantation2.94 (2.40–3.61)
Predictors of in-hospital mortality with DRI (multivariate) — Malnutrition vs CIED implantation2.50 (1.99–3.15)

%

OutcomeDRICIED implantationEstimateP value
Male sex69.3Not reported in the abstractP < 0.001
Charlson comorbidity index ≥346.6Not reported in the abstractP < 0.001
In-hospital mortality with DRI (annual)
4.4% · mean · range 3.9–5.8%
In-hospital mortality with DRI (annual) — Trend in annual in-hospital mortality
P value for trend = 0.07
  • Male sex: No DRI 57%
  • Charlson comorbidity index ≥3: No DRI 36.8%

In-hospital mortality with DRI (annual)

Prevalence of congestive heart failure (CHF) increased in DRI admissions over the observation period

Safety

Most common complications with DRI
4.1 · PE · DVT 3.6 · Post-procedural hematoma 2.90%

Original publication

Cardiac implantable electronic device implantation and device-related infection. Europace. Published 11 August 2023. doi:10.1093/europace/euad208