Heart failure & cardiomyopathies

Class 1C Antiarrhythmics for Premature Ventricular Complex Suppression in Nonischemic Cardiomyopathy With Implantable Cardioverter-Defibrillators

JACC Clin ElectrophysiolPublished Retrospective cohort study

Authors' conclusion

Class 1C AADs effectively suppressed PVCs in patients with NICM and ICDs, leading to increases in LVEF and biventricular pacing percentage. In this limited sample, their use was safe.

Study context

Population
Patients with nonischemic cardiomyopathy and implantable cardioverter-defibrillators (ICDs) treated with flecainide or propafenone, Hospital of the University of Pennsylvania, 2014–202223 flecainide, 11 propafenone
Participants
34 patients
Exposure
During vs before class 1C AAD treatment
Outcome
PVC burden, LVEF and biventricular pacing percentage before vs during class 1C AAD treatment
Methodological detailssingle-centre, before–after comparison, Most patients had failed other AADs (62%) or catheter ablation (68%) before class 1C AAD initiation
  • Single-centre
  • Before–after comparison
  • Most patients had failed other AADs (62%) or catheter ablation (68%) before class 1C AAD initiation

Main finding

As reported in the abstract

PVC burden
Left ventricular ejection fraction (LVEF) increased from 33% ± 9% to 37% ± 10%
P = 0.01
Biventricular pacing percentage increased from 85% ± 9% to 93% ± 7%
P = 0.01

Observational data: associations, not effects.

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

Class 1C Antiarrhythmics for Premature Ventricular Complex Suppression in Nonischemic Cardiomyopathy With Implantable Cardioverter-Defibrillators. JACC Clin Electrophysiol. Published 27 March 2024. doi:10.1016/j.jacep.2024.01.021

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.