Coronary disease & ACS

Comparative Effectiveness of Positron Emission Tomography (PET) and Single-photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging (MPI) for Predicting Cardiovascular Events After Kidney Transplant

Circ Cardiovasc ImagingPublished Retrospective cohort study

Authors' conclusion

Kidney transplant recipients are at high cardiovascular risk, despite a minority having obstructive coronary artery disease on MPI. PET MPI findings predict posttransplant MACE.

Study context

Population
Patients undergoing MPI before kidney transplant58 [15%] abnormal MPI
Participants
393 patients
Exposure
Pretransplant PET MPI vs SPECT MPI for predicting posttransplant MACE
  • PETn = 208
  • SPECTn = 185
Outcome
Posttransplant MACE (MI, stroke, HF, cardiac death); abnormal MPI = total perfusion deficit >5% of myocardium
Follow-up
Median 5.9 years
Methodological detailspropensity-weighted
  • Propensity-weighted

Main finding

As reported in the abstract

Association of abnormal MPI with posttransplant MACE
Propensity-weighted
Hazard ratio (95% CI)P value
Abnormal PETvs Normal PET
3.02(1.78–5.11)
P < 0.001
Abnormal SPECTvs Normal SPECT
1.39(0.72–2.66)
P = 0.33
Explained relative risk (R2), PET vs SPECT
0.086 versus 0.007

Observational data: associations, not effects.

Further findings

OutcomePETSPECTP value
MACE rate with normal MPINormal results2.2%/year3.6%/yearP < 0.001

Original publication

Comparative Effectiveness of PET and SPECT MPI for Predicting Cardiovascular Events After Kidney Transplant. Circ Cardiovasc Imaging. Published 16 January 2024. doi:10.1161/circimaging.123.015858