Comparison of cardiac troponin assays reveals assay-specific sensitivities in a clinical model of very acute myocardial injury

Eur Heart J Acute Cardiovasc CarePublished Diagnostic accuracy study

Authors' conclusion

The Atellica assay demonstrated enhanced sensitivity for very acute myocardial injury, likely via its additional recognition of the proximally located cTnI epitope.

Study context

Population
Patients undergoing pulmonary vein isolation (left-atrial ablation) as a clinical model of acute myocardial injuryplus 48 routine post-ablation cohort
Participants
158 patients
Comparison
Atellica-IM hs-cTnI vs Architect hs-cTnI vs Elecsys hs-cTnT
Outcome
Relative pre-to-post-procedural cTn concentration increase and cTnI/T ratios by assay
Methodological detailsprospective
  • Prospective

Performance

As reported in the abstract

Pre-to-post-procedural cTnI concentration increase

Atellica-IM-cTnI

39.6-fold

Architect-cTnI

20.5-fold

P = 0.0036

Further findings

≥1 post-procedural cTn concentration above acute myocardial infarction (AMI) rule-in thresholds

Patients with ≥1 post-procedural cTn above AMI rule-in thresholds
78%

Predictors of pre-to-post increase

CKD predicted higher pre-to-post increases

Routine clinical cTn after ablation (n = 48, retrospective)

cTn levels after ablation did not correlate with symptoms, ECG changes or angiography findings

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

Comparison of cardiac troponin assays reveals assay-specific sensitivities in a clinical model of very acute myocardial injury. Eur Heart J Acute Cardiovasc Care. Published 25 April 2025. doi:10.1093/ehjacc/zuaf064

Summarised from the published abstract; every number is checked against it

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.