Arrhythmias & electrophysiology

Deep sedation protocol during atrial fibrillation ablation using a novel variable-loop biphasic pulsed field ablation catheter

EuropacePublished Descriptive analysis within the inspIRE trial

Authors' conclusion

During PFA ablation procedures with the variable-loop circular catheter and its accompanying biphasic pulse, our deep sedation protocol is a valid alternative to general anesthesia.

Study context

Population
Patients undergoing pulsed field ablation (PFA) for paroxysmal atrial fibrillation (AF) in the inspIRE trial
Participants
29 patients
Outcome
Sedation and analgesia scores
Follow-up
During procedure

Main finding

As reported in the abstract

Richmond Agitation-Sedation Scale (RASS) −1 to −5
27 (93%)
RASS 0
2 (7%)
Visual Analogue Scale (VAS) 0 to 2
24 (83%)
VAS 3
3 (10%)
VAS 4
2 (7%)
PSI <50
16 (55%)
PSI 50 to 70
9 (31%)

Safety

Procedural complications, need for non-invasive ventilation or intubation

Procedural complications
0
Non-invasive ventilation or tracheal intubation required
0
Sufficient oxygen saturation maintained in all patients

Original publication

Deep sedation protocol during atrial fibrillation ablation using a novel variable-loop biphasic pulsed field ablation catheter. Europace. Published 20 July 2023. doi:10.1093/europace/euad222