Authors' conclusion

The 2023 ESC and 2023 Duke-ISCVID classifications had a higher sensitivity but a lower specificity than the 2015 ESC classification in patients with CIEDs, especially among those with lead IE. In patients with CIEDs, the 2019 EHRA classification was the most accurate.

Study context

Population
Patients treated for infective endocarditis (IE) between January 2017 and October 2022, with or without cardiac implantable electronic devices (CIEDs)patients treated for IE · patients with CIEDs 269 · patients with CIEDs and lead IE 159 · patients without CIEDs 911
Participants
1,180 patients
Exposure
We compared the performance of the 2023 European Society of Cardiology (ESC) classification to that of 2015 ESC, 2019 European Heart Rhythm Association (EHRA) and 2023 Duke-International Society for Cardiovascular Infectious Diseases (ISCVID) classifications; gold standard: expert-adjudicated 'certain' IE
Outcome
Sensitivity and specificity in patients with CIEDs

Main finding

As reported in the abstract

GroupSensitivitySpecificity
2023 Duke-ISCVID97.1%31.1%
2023 ESC93.8%41.0%

Sensitivity

2023 Duke-ISCVID97.1%
2023 ESC93.8%

Specificity

2023 Duke-ISCVID31.1%
2023 ESC41.0%
Adjudicated as 'certain IE' (of the 269 patients with CIEDs)
208 (77.3%)

Observational data: associations, not effects.

Further findings

Specificity

Outcome2023 ESC2015 ESC2019 EHRA2023 Duke-ISCVID
Specificity in patients with CIEDs and lead IE32.4%Not reported in the abstract67.6%11.8%2015 ESC: not reported in the abstract
Sensitivity and specificity in patients without CIEDs48.0%55.5%Not reported in the abstract52.6%2019 EHRA: not reported in the abstract
Specificity in patients with CIEDs and lead IE — 'certain IE' among the 159 patients with CIEDs and lead IE
78.6%
Sensitivity and specificity in patients without CIEDs — 'certain IE' among the 911 patients without CIEDs
81.0%
Sensitivity and specificity in patients without CIEDs — Sensitivity for all classifications
higher than 96%

Specificity in patients with CIEDs and lead IE

Sensitivity remained high for all classifications