Heart failure & cardiomyopathies

Digoxin and Risk of Ventricular Tachyarrhythmia and Death in Implantable Cardioverter-defibrillator (ICD) Recipients

JACC Clin ElectrophysiolPublished Secondary analysis of the MADIT randomised trials

Authors' conclusion

Our findings suggests that digoxin use is associated with ventricular tachyarrhythmia and death in heart failure with reduced ejection fraction patients with an ICD.

Study context

Population
HFrEF patients with a primary prevention ICD or CRT-defibrillator enrolled in 4 MADIT trials
Participants
4,499 patients
Comparison
Digoxin vs no digoxin
  • Digoxinn = 1,155
Primary endpoint
First and recurrent VT/VF and all-cause mortality
Methodological detailspropensity-score quintile stratification, multivariable adjustment, competing risk of death adjustment, 4 pooled MADIT trials
  • Propensity-score quintile stratification
  • Multivariable adjustment
  • Competing risk of death adjustment
  • 4 pooled MADIT trials

Primary result

As reported in the abstract

VT/VF
48% increased risk of VT/VF with digoxin
P < 0.001

Further findings

OutcomeHRP value
Appropriate ICD shocks1.91P < 0.001
Burden of VT/VF events1.46P = 0.001

VT/VF or death (composite)

42% increased risk with digoxin
P < 0.001

All-cause mortality

37% increased risk with digoxin
P = 0.006

Original publication

Digoxin and Risk of Ventricular Tachyarrhythmia and Death in ICD Recipients. JACC Clin Electrophysiol. Published 12 June 2024. doi:10.1016/j.jacep.2024.03.042

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.