Heart failure & cardiomyopathies
Digoxin and Risk of Ventricular Tachyarrhythmia and Death in Implantable Cardioverter-defibrillator (ICD) Recipients
Authors' conclusion
Our findings suggests that digoxin use is associated with ventricular tachyarrhythmia and death in heart failure with reduced ejection fraction patients with an ICD.
Study context
- Population
- HFrEF patients with a primary prevention ICD or CRT-defibrillator enrolled in 4 MADIT trials
- Participants
- 4,499 patients
- Comparison
- Digoxin vs no digoxin
- Digoxinn = 1,155
- Primary endpoint
- First and recurrent VT/VF and all-cause mortality
Methodological detailspropensity-score quintile stratification, multivariable adjustment, competing risk of death adjustment, 4 pooled MADIT trials
- Propensity-score quintile stratification
- Multivariable adjustment
- Competing risk of death adjustment
- 4 pooled MADIT trials
Primary result
As reported in the abstract
VT/VF
- 48% increased risk of VT/VF with digoxin
- P < 0.001
Key notes
- Propensity score quintile stratification
Further findings
| Outcome | HR | P value |
|---|---|---|
| Appropriate ICD shocks | 1.91 | P < 0.001 |
| Burden of VT/VF events | 1.46 | P = 0.001 |
VT/VF or death (composite)
- 42% increased risk with digoxin
- P < 0.001
All-cause mortality
- 37% increased risk with digoxin
- P = 0.006
Original publication
Digoxin and Risk of Ventricular Tachyarrhythmia and Death in ICD Recipients. JACC Clin Electrophysiol. Published 12 June 2024. doi:10. 1016/ j. jacep. 2024. 03. 042