Discordance between left atrial pressure and risk scores in assessment of heart failure with preserved ejection fraction in patients with atrial fibrillation undergoing catheter ablation

EuropacePublished Cohort study

Authors' conclusion

Over one-third of catheter ablation patients had elevated LAP.

Study context

Population
Symptomatic atrial fibrillation (AF) patients undergoing catheter ablation (median age 65 years, 41% female)
Participants
336 patients
Exposure
Elevated left atrial pressure (LAP) vs non-elevated LAP
  • Elevated LAPn = 125
Outcome
Prevalence of and factors associated with elevated LAP; concordance between elevated LAP and HFpEF risk scores

Main finding

As reported in the abstract

Elevated LAP (mean LAP ≥ 15 mmHg)

Elevated LAP

37%

125

Higher body mass index (BMI) associated with elevated LAP
OR 1.21 (1.11-1.31) (95% CI)
Lower LA reservoir strain associated with elevated LAP
OR 0.97 (0.94-0.99) (95% CI)

Observational data: associations, not effects.

Further findings

12 months

AF recurrence

P = 0.775

Repeat ablations

P = 0.230

High heart failure with preserved ejection fraction (HFpEF) probability (H2FPEF ≥ 6 and/or HFA-PEFF ≥ 5)

High HFpEF probability among 204 eligible patients
36%

Safety

Severe adverse events (death, life-threatening situations, hospitalizations or persistent disability) · 12 months

P = 0.044

Original publication

Discordance between left atrial pressure and risk scores in assessment of heart failure with preserved ejection fraction in patients with atrial fibrillation undergoing catheter ablation. Europace. Published 9 October 2025. doi:10.1093/europace/euaf245

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.