Arrhythmias & electrophysiology

Fascicular Substrate Modification to Treat Human Ventricular Fibrillation

JACC Clin ElectrophysiolPublished Single-centre case series

Authors' conclusion

Catheter ablation of human VF and PMVT with FSM is feasible and safe and appears highly effective, with high rates of acute VF noninducibility and long-term freedom from recurrent VF.

Study context

Population
Patients with ventricular fibrillation (VF) or polymorphic ventricular tachycardia (PMVT) undergoing catheter ablation, ≥2 failed antiarrhythmic drugsof 2,212 ablation patients
Participants
18 patients
Exposure
Idiopathic VF vs Underlying cardiomyopathy
  • Idiopathic VFn = 11
  • Underlying cardiomyopathyn = 7
Outcome
Arrhythmia free on or off drugs
Follow-up
Median 24 months
Methodological detailsconsecutive patients, prospectively collected institutional database
  • Consecutive patients
  • Prospectively collected institutional database

Main finding

As reported in the abstract

P = 0.06

Overall arrhythmia free
16 patients (88.9%)

Observational data: associations, not effects.

Safety

No procedure-related complications
No new fascicular block or bundle branch block

Original publication

Fascicular Substrate Modification to Treat Human Ventricular Fibrillation. JACC Clin Electrophysiol. Published 12 June 2024. doi:10.1016/j.jacep.2024.03.035

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.