Acute cardiac care & resuscitation

Hemodynamic effects of TEE–guided adjustment of the area of the maximal compressions during cardiopulmonary resuscitation

ResuscitationPublished prospective enrolment

Authors' conclusion

2D-TEE-guided identification and adjustment of AMC allowed targeted optimization of chest compressions. Approximately 80% of patients required AMC adjustment. 3D-TEE was used to quantify LV parameters. In patients undergoing AMC adjustment, significant improvements in SV and EF were observed, reaching levels comparable to those without adjustment.

Study context

Population
Adult patients with non-traumatic out-of-hospital cardiac arrest (OHCA)patients included
Participants
19 patients
Exposure
Left ventricular (LV) parameters during resuscitation with and without area of maximal compression (AMC) adjustment
  • AMC-LV groupn = 4
  • AMC-non-LV groupn = 15
Outcome
AMC location

Main finding

As reported in the abstract

Observational data: associations, not effects.

Further findings

ROSC rates · did not differ

P = 0.603

Stroke volume (SV), ejection fraction (EF) and EtCO2 before vs after adjustment in the AMC-non-LV group
9 vs. 28.6 mL, p = 0.004 · SV · EF 20.4 vs. 60.8%, p < 0.0001 · EtCO2 19 vs. 42 mmHg, p < 0.0001

SV, EF and EtCO2 before vs after adjustment in the AMC-non-LV group

Increased significantly post-adjustment, reaching values comparable to the AMC-LV group

Original publication

Hemodynamic effects of TEE–guided adjustment of the area of the maximal compressions during cardiopulmonary resuscitation. Resuscitation. Published 14 April 2026. doi:10.1016/j.resuscitation.2026.111097

Composed by AI from the published abstract and checked against it. How Briefs are made →