Coronary disease & ACS

Impact of cardiac size on diagnostic performance of single-photon emission computed tomography myocardial perfusion imaging: insights from the REgistry of Fast Myocardial Perfusion Imaging with NExt generation single-photon emission computed tomography

Eur Heart J Cardiovasc ImagingPublished Diagnostic accuracy study

Authors' conclusion

Detection of CAD with SPECT MPI is negatively impacted by small cardiac size, most notably in elderly and male patients.

Study context

Population
Patients without known coronary artery disease (CAD) undergoing single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) followed by coronary angiography (REFINE SPECT registry)
Participants
2,066 patients9 institutions
Comparison
SPECT MPI diagnostic performance by cardiac size, age and sex
Outcome
AUC of SPECT MPI for detecting obstructive CAD, by cardiac size
Methodological detailsmulticentre registry, nine institutions, solid-state scanners
  • Multicentre registry
  • Nine institutions
  • Solid-state scanners

Performance

As reported in the abstract

AUC for obstructive CAD by EDV
Test or modelAUC (population threshold)AUC (sex-specific threshold)
Low end-diastolic volume (EDV)0.720.72
Normal EDV0.780.79

AUC (population threshold)

Low end-diastolic volume (EDV)0.72
Normal EDV0.78

AUC (sex-specific threshold)

Low end-diastolic volume (EDV)0.72
Normal EDV0.79
  • Low EDV vs Normal EDV: P = 0.03 — population threshold: 0.72 vs 0.78
  • Low EDV vs Normal EDV: P = 0.01 — sex-specific threshold: 0.72 vs 0.79

Further findings

AUC by age (elderly ≥75 vs <75 years)

AUC elderly vs younger patients
0.72 vs. 0.78, P = 0.03

AUC by sex (males vs females)

AUC males vs females, similar
0.77 vs. 0.76, P = 0.67

AUC, lower vs non-low EDV in males (sex-specific threshold) (subgroup)

Reduction in accuracy with lower volumes primarily in males
0.69 vs. 0.79, P = 0.01

Patients with ≥2 of low EDV, elderly age or male sex

Significant decrease in AUC, sensitivity, specificity and NPV for quantitative and visual assessments

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

Impact of cardiac size on diagnostic performance of single-photon emission computed tomography myocardial perfusion imaging: insights from the REgistry of Fast Myocardial Perfusion Imaging with NExt generation single-photon emission computed tomography. Eur Heart J Cardiovasc Imaging. Published 6 March 2024. doi:10.1093/ehjci/jeae055

Composed by AI from the published abstract and checked against it. How Briefs are made →