Arrhythmias & electrophysiologyCohort study

Impact of Device Implant Depth After Left Atrial Appendage Occlusion

JACC Cardiovasc IntervPublished

  • Multicentre cohort study
  • 9 centres in Europe and Canada

Authors' conclusion

LAAO device implantation depth is an independent risk factor for DRT. Deeper device implantation and larger uncovered left atrial appendage areas were associated with a higher incidence of DRT.

Study context

Population
Patients with successful left atrial appendage occlusion (LAAO) at 9 centres in Europe and Canada
Participants
1,317 patients
Exposure
Proximal vs distal LAAO device implantation
  • Proximaln = 732reference
  • Distaln = 585
Outcome
Device-related thrombus (DRT)
Follow-up
follow-up

Main finding

DRT

Hazard ratio

5.92

95% CI 3.39–10.36

By group

Distal vs Proximal
HR 5.92 (95% CI 3.39–10.36)

As reported in the abstract

Observational data: associations, not effects.

Further findings

OutcomeHR (95% CI)
DRT predictor: no or single antiplatelet therapy · multivariable analysis; independent predictor1.62 (0.99–2.62)

Procedural outcomes

No differences in procedural outcomes between the groups

Device-related thrombus (DRT) by implant depth and uncovered LAA area

Deeper implantation and larger uncovered LAA area associated with higher DRT incidence, regardless of device type
P < 0.001

Original publication

Impact of Device Implant Depth After Left Atrial Appendage Occlusion. JACC Cardiovasc Interv. Published 9 August 2023. doi:10.1016/j.jcin.2023.05.045

Summarised from the published abstract; every number is checked against it