Arrhythmias & electrophysiology

Incidence, Predictors, and Clinical Outcomes of Device-Related Thrombus in the Amulet IDE Trial

JACC Clin ElectrophysiolPublished Secondary analysis of the Amulet IDE randomised trial

Authors' conclusion

Incidence of DRT following LAAO was low. Early DRTs are seen with the dual occlusive mechanism device and late DRTs are seen with the single occlusive mechanism device.

Study context

Population
Patients with successful left atrial appendage occlusion (LAAO) implant in the Amulet IDE trialsuccessful implants
Participants
903 vs 885
Comparison
Amulet vs Watchman LAAO device
  • Amuletn = 903
  • Watchmann = 885reference
Primary endpoint
Incidence of DRT (by transesophageal echocardiography)
Follow-up
18 months

Primary result

As reported in the abstract

DRT incidence
Overall device-related thrombus (DRT) incidence
3.9% (n = 70)

Further findings

Predictors of DRT

HR (95% CI)P value
AF at time of procedure2.44 (1.42–4.22)P < 0.01
Female sex1.65 (1.01–2.71)P = 0.04
Older age1.04 (1.01–1.08)P = 0.02
OutcomeHR (95% CI)P value
CV mortality, DRTvs non-DRT2.33 (1.01–5.39)P = 0.04
OutcomeAmuletWatchman
Timing of DRT (early ≤45 days vs late >45 days)
Early DRT19 of 31— not stated in the abstract
Late DRT— not stated in the abstract31 of 42

— not stated in the abstract

  • CV mortality, DRT vs non-DRT: DRT 8.7%
  • CV mortality, DRT vs non-DRT: Non-DRT 3.9%

Safety

Events

OutcomeAmuletWatchman
Stroke following DRT03

Original publication

Incidence, Predictors, and Clinical Outcomes of Device-Related Thrombus in the Amulet IDE Trial. JACC Clin Electrophysiol. Published 28 September 2022. doi:10.1016/j.jacep.2022.07.014

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.