Arrhythmias & electrophysiology

Left atrial appendage closure in patients with left atrial appendage thrombus guided by intracardiac echocardiography

Heart RhythmPublished Case series

Authors' conclusion

LAAC using the LAmbre device guided by ICE may be feasible in patients with LAA thrombus when performed by experienced operators.

Study context

Population
Patients with persistent left atrial appendage (LAA) thrombus despite anticoagulation or contraindications to anticoagulation, June 2021–April 2023mean age 65 ± 7 years
Participants
12 patients
Outcome
Feasibility of LAAC: periprocedural events and clinical outcomes during follow-up
Methodological detailssingle-group
  • Single-group

Main finding

As reported in the abstract

Feasibility
Device successfully implanted in all patients
12
Severe periprocedural complications
0
Thrombus location: apex
6
Thrombus location: body
3
Thrombus location: ostium
3

Observational data: associations, not effects.

Further findings

No device-related thrombus or peridevice leak > 3 mm detected; all completed TEE follow-up

Safety

Stroke/TIA, systemic embolism or major bleeding · median follow-up 147 days (IQR 80-306 days)

No patient experienced stroke/TIA, systemic embolism or major bleeding

Original publication

Left atrial appendage closure in patients with left atrial appendage thrombus guided by intracardiac echocardiography. Heart Rhythm. Published 23 January 2024. doi:10.1016/j.hrthm.2024.01.028

Summarised from the published abstract; every number is checked against it

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.