Valvular & structural heart disease

Long-Term Risk of Stroke After Transcatheter Aortic Valve Replacement: Insights From the SwissTAVI Registry

JACC Cardiovasc IntervPublished Registry-based cohort study

Authors' conclusion

Compared with an age- and sex-matched population, TAVR patients experienced a higher risk of stroke for up to 2 years after the procedure, and a comparable risk thereafter.

Study context

Population
Consecutive patients undergoing transcatheter aortic valve replacement (TAVR) in Switzerland, February 2011 to June 2021
Participants
11,957 patients
Exposure
TAVR population vs age- and sex-matched Swiss general population
  • TAVRn = 11,957
Outcome
Short- and long-term incidence of stroke after TAVR; Standardized stroke ratios (SSRs) vs matched general population
Methodological detailsconsecutive patients, national registry (SwissTAVI)
  • Consecutive patients
  • National registry (SwissTAVI)

Main finding

As reported in the abstract

Stroke incidence after TAVR

TAVR

30-day cumulative incidence
3.0%
1-year incidence
4.3%
5-year incidence
7.8%

TAVR

30-day cumulative incidence3.0%
1-year incidence4.3%
5-year incidence7.8%

SSR

First year, males
7.26 (95% CI 6.3–8.36)
First year, females
6.82 (95% CI 5.97–7.79)
Second year, males
1.98 (95% CI 1.47–2.67)
Second year, females
1.48 (95% CI 1.09–2.02)

Observational data: associations, not effects.

Original publication

Long-Term Risk of Stroke After Transcatheter Aortic Valve Replacement: Insights From the SwissTAVI Registry. JACC Cardiovasc Interv. Published 25 December 2023. doi:10.1016/j.jcin.2023.10.021

Summarised from the published abstract; every number is checked against it

Get them every week

New studies on this topic in My Week and in your Monday e-mail.