Valvular & structural heart disease
Long-Term Risk of Stroke After Transcatheter Aortic Valve Replacement: Insights From the SwissTAVI Registry
Authors' conclusion
Compared with an age- and sex-matched population, TAVR patients experienced a higher risk of stroke for up to 2 years after the procedure, and a comparable risk thereafter.
Study context
- Population
- Consecutive patients undergoing transcatheter aortic valve replacement (TAVR) in Switzerland, February 2011 to June 2021
- Participants
- 11,957 patients
- Exposure
- TAVR population vs age- and sex-matched Swiss general population
- TAVRn = 11,957
- Outcome
- Short- and long-term incidence of stroke after TAVR; Standardized stroke ratios (SSRs) vs matched general population
Methodological detailsconsecutive patients, national registry (SwissTAVI)
- Consecutive patients
- National registry (SwissTAVI)
Main finding
As reported in the abstract
Stroke incidence after TAVR
TAVR
- 30-day cumulative incidence
- 3.0%
- 1-year incidence
- 4.3%
- 5-year incidence
- 7.8%
TAVR
30-day cumulative incidence3.0%
1-year incidence4.3%
5-year incidence7.8%
SSR
- First year, males
- 7.26 (95% CI 6.3–8.36)
- First year, females
- 6.82 (95% CI 5.97–7.79)
- Second year, males
- 1.98 (95% CI 1.47–2.67)
- Second year, females
- 1.48 (95% CI 1.09–2.02)
Observational data: associations, not effects.
Original publication
Long-Term Risk of Stroke After Transcatheter Aortic Valve Replacement: Insights From the SwissTAVI Registry. JACC Cardiovasc Interv. Published 25 December 2023. doi:10. 1016/ j. jcin. 2023. 10. 021
Summarised from the published abstract; every number is checked against it