Nitroglycerin to Ameliorate Coronary Artery Spasm During Focal Pulsed-Field Ablation for Atrial Fibrillation
Authors' conclusion
Ablation of the cavotricuspid isthmus using a focal PFA catheter routinely provokes right coronary vasospasm. Pretreatment with high doses of parenteral nitroglycerin prevents severe spasm.
Study context
- Population
- Patients undergoing AF ablation with cavotricuspid isthmus ablation using a focal pulsed-field ablation (PFA) catheter
- Participants
- 5 / 10 / 10 / 8
- Comparison
- Nitroglycerin strategies vs no nitroglycerin during focal PFA of the cavotricuspid isthmus
- No nitroglycerinn = 5reference
- Multiple bolusesn = 10
- Bolus + infusionn = 10
- Testing strategiesn = 8
- Outcome
- Right coronary artery vasospasm on angiography (some with fractional flow reserve)
- Follow-up
- Before, during, and after PFA
Main finding
As reported in the abstract
Right coronary vasospasm
| Group | Value | Moderate-severe vasospasm | Fractional flow reserve | Severe spasm | Mild-moderate vasospasm | Mild-moderate spasm |
|---|---|---|---|---|---|---|
| No nitroglycerin | 80% | 4 of 5 (80%) | 0.71 ± 0.08 | — not stated in the abstract | — not stated in the abstract | — not stated in the abstract |
| Multiple boluses | 20% | — not stated in the abstract | — not stated in the abstract | 0 | 2 of 10 (20%) | — not stated in the abstract |
| Bolus + infusion | 40% | — not stated in the abstract | — not stated in the abstract | 1 of 10 | — not stated in the abstract | 3 of 10 |
Value
No nitroglycerin80%
Multiple boluses20%
Bolus + infusion40%
Moderate-severe vasospasm
No nitroglycerin4 of 5 (80%)
Multiple boluses— not stated in the abstract
Bolus + infusion— not stated in the abstract
Fractional flow reserve
No nitroglycerin0.71 ± 0.08
Multiple boluses— not stated in the abstract
Bolus + infusion— not stated in the abstract
Severe spasm
No nitroglycerin— not stated in the abstract
Multiple boluses0
Bolus + infusion1 of 10
Mild-moderate vasospasm
No nitroglycerin— not stated in the abstract
Multiple boluses2 of 10 (20%)
Bolus + infusion— not stated in the abstract
Mild-moderate spasm
No nitroglycerin— not stated in the abstract
Multiple boluses— not stated in the abstract
Bolus + infusion3 of 10
Safety
- No patient had ST-segment changes
Original publication
Nitroglycerin to Ameliorate Coronary Artery Spasm During Focal Pulsed-Field Ablation for Atrial Fibrillation. JACC Clin Electrophysiol. Published 21 February 2024. doi:10. 1016/ j. jacep. 2023. 12. 015