Arrhythmias & electrophysiology

Patient-Reported Symptoms and Arrhythmias During Continuous ECG Monitoring After Transcatheter Aortic Valve Implantation

Heart RhythmPublished prospective

Authors' conclusion

After TAVI, patient-triggered events during ECG patch monitoring poorly reflect objectively documented arrhythmias and fail to identify many clinically relevant rhythm disturbances. These findings support systematic continuous ECG surveillance beyond symptom-driven monitoring strategies after TAVI.

Study context

Population
Adult patients undergoing transcatheter aortic valve implantation (TAVI) at a Swiss tertiary centre, monitored with a 14-day ECG patch before discharge
Participants
315 patients
Outcome
Patient-triggered events
Follow-up
14-day monitoring
Methodological detailssingle Swiss tertiary centre, 14-day ECG patch monitoring
  • Single Swiss tertiary centre
  • 14-day ECG patch monitoring

Main finding

As reported in the abstract

Patient-triggered events

Patients with at least one patient-triggered event

94 patients

30%

Median events per patient

2

1–4

Further findings

Atrial fibrillation

Atrial fibrillation (AF) detected
85 patients (27%)
Patients with AF who reported symptoms during AF episodes
20 patients with AF (24%)
New AF 17 patients (5.4%)

Pauses and high-grade atrioventricular block

Patients

Pauses
58 (18%)
High-grade atrioventricular block
32 (10%)
No associated patient-triggered events

Ventricular tachycardia (≥4 beats)

Ventricular tachycardia (≥4 beats)
165 patients (52%)
Entirely asymptomatic

Rhythm findings during symptom-triggered events

Evaluable symptom-triggered events without associated arrhythmia
153 (44%) of 348
Premature atrial contractions
21%
AF
14%
Premature ventricular contractions
11%

Monitoring duration

Median analyzable duration
14 days [13-14]

Original publication

Patient-Reported Symptoms and Arrhythmias During Continuous ECG Monitoring After Transcatheter Aortic Valve Implantation. Heart Rhythm. Published 17 November 2026. doi:10.1016/j.hrthm.2026.11.015

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.