Arrhythmias & electrophysiology
Biatrial Versus Left Atrial Maze Ablation During Cardiac Valve Surgery for Persistent Atrial Fibrillation: The ABLATION Trial
Primary result · Freedom from atrial tachyarrhythmias lasting >30 seconds without antiarrhythmic drugsResult — go to the resultAdjusted difference 10.7% 1-sided lower 95% CI 3%Authors' conclusion
Among patients with persistent or long-standing persistent AF undergoing rheumatic cardiac valve surgery, biatrial maze ablation was superior to LA maze ablation in reducing recurrent atrial tachyarrhythmias, while maintaining noninferiority with respect to permanent pacemaker implantation. These findings provide direct evidence to inform lesion-set selection for surgical ablation during cardiac surgery.
Study context
- Population
- Patients with persistent or long-standing persistent atrial fibrillation (AF) undergoing rheumatic mitral valve surgery, with or without concomitant cardiac surgical procedures
- Participants
- 323 patients
- Comparison
- Biatrial vs left atrial maze ablation
- Biatrialn = 164
- Left atrial (LA)n = 159
- Primary endpoint
- Freedom from atrial tachyarrhythmias lasting >30 seconds without antiarrhythmic drugs
- Follow-up
- 12 months
Methodological details1:1 randomization, surgeons underwent pretrial training and certification, procedures videorecorded and centrally reviewed, intention-to-treat analysis
- 1:1 randomization
- Surgeons underwent pretrial training and certification
- Procedures videorecorded and centrally reviewed
- Intention-to-treat analysis
Primary result
As reported in the abstract
Freedom from atrial tachyarrhythmias lasting >30 seconds without antiarrhythmic drugs
Biatrialvs LA
adjusted difference 10.7% (1-sided lower 95% CI 3%); P = 0.01
Key notes
- Higher with Biatrial
- Intention-to-treat analysis
Secondary outcomes
| Outcome | Biatrial | LA | Adjusted difference (1-sided lower 95% CI) | P value | |
|---|---|---|---|---|---|
| Freedom from permanent pacemaker implantation (key secondary end point) | 97.0% | 98.1% | −1.1% (−3.9%) | P for non-inferiority = 0.01 | |
| −4−202Difference (linear scale) |
- Freedom from permanent pacemaker implantation (key secondary end point): noninferiority margin of −5%; predefined noninferiority criterion met
Original publication
Biatrial Versus Left Atrial Maze Ablation During Cardiac Valve Surgery for Persistent Atrial Fibrillation: The ABLATION Trial. Circulation. Published 16 November 2026. doi:10. 1161/ circulationaha. 126. 083005
Composed by AI from the published abstract and checked against it. How Briefs are made →