Arrhythmias & electrophysiology

Personalized Heart Digital Twins Detect Substrate Abnormalities in Scar-Dependent Ventricular Tachycardia

CirculationPublished Prospective diagnostic accuracy study

Authors' conclusion

Digital twin-predicted sites display a higher prevalence of abnormal and prolonged electrograms compared with nonpredicted sites and accurately identify regions of conduction slowing.

Study context

Population
Patients with scar-dependent ventricular tachycardia (VT) undergoing catheter ablationpatients with scar-dependent VT
Participants
18 patients
Comparison
Digital twin-predicted sites vs nonpredicted sites
Outcome
Electrogram abnormalities and regions of conduction slowing at digital twin-predicted vs nonpredicted sites

Performance

As reported in the abstract

Electrogram abnormalities

P < 0.001

Further findings

Electrogram duration

P < 0.001

Deceleration zones on isochronal late activation mapping correctly identified

Deceleration zones correctly identified by digital twins
21 of 26 (80.8%)

Original publication

Personalized Heart Digital Twins Detect Substrate Abnormalities in Scar-Dependent Ventricular Tachycardia. Circulation. Published 6 January 2025. doi:10.1161/circulationaha.124.070526

Summarised from the published abstract; every number is checked against it

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.