Coronary disease & ACS

Polymer-free versus biodegradable-polymer drug-eluting stent in patients undergoing percutaneous coronary intervention: an assessor-blind, non-inferiority, randomised controlled trial

EuroInterventionPublished randomised, investigator-initiated, assessor-blind, non-inferiority trial

Primary result · Device-oriented composite endpoint (cardiovascular death, target vessel myocardial infarction, or target lesion revascularisation)Result — go to the resultRisk difference 1% 1-sided 95% CI upper limit 2.9%

Authors' conclusion

In all-comer patients undergoing PCI, polymer-free AES were non-inferior to biodegradable-polymer EES at 1-year follow-up in terms of a device-oriented composite endpoint despite being associated with an increased risk of early stent thrombosis.

Study context

Population
All-comer patients undergoing percutaneous coronary intervention (PCI)patients with 3,042 coronary lesions randomised
Participants
2,107 patients
Comparison
Polymer-free amphilimus-eluting stent (AES) vs biodegradable-polymer everolimus-eluting stent (EES)
  • Polymer-free AESn = 1,051
  • Biodegradable-polymer EESn = 1,056reference
Primary endpoint
Device-oriented composite endpoint:
  • Cardiovascular death
  • Target vessel myocardial infarction
  • Target lesion revascularisation
Follow-up
1-year follow-up
Methodological details14 hospitals in Italy
  • 14 hospitals in Italy

Primary result

As reported in the abstract

Risk difference

1%

1-sided 95% CI upper limit 2.9%

P = 0.041 for non-inferiority

Events by treatment group

Polymer-free AESvs biodegradable-polymer EES
risk difference 1% (1-sided 95% CI upper limit 2.9%); P for non-inferiority = 0.041

Further findings

There were no significant differences in the incidence of the components of the primary endpoint between groups

Safety

OutcomePolymer-free AESBiodegradable-polymer EESHazard ratio (95% CI)P value
Definite or probable stent thrombosis1.0%0.3%3.72 (1.04–13.33)P = 0.044
  • Definite or probable stent thrombosis: due to an increased risk of early stent thrombosis within 30 day

Original publication

Polymer-free versus biodegradable-polymer drug-eluting stent in patients undergoing percutaneous coronary intervention: an assessor-blind, non-inferiority, randomised controlled trial. EuroIntervention. Published 6 January 2025. doi:10.4244/eij-d-24-00657

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.