Heart failure & cardiomyopathies

Postdevelopment Performance and Validation of the Artificial Intelligence-Enhanced Electrocardiogram for Detection of Cardiac Amyloidosis

JACC AdvPublished Diagnostic accuracy study

Authors' conclusion

The AI-ECG for the detection of CA maintained an overall strong performance with respect to patient age, sex, race, and amyloid subtype.

Study context

Population
Patients with cardiac amyloidosis diagnosed after algorithm development and matched controls with a 12-lead electrocardiogram (ECG)
Participants
440 vs 6,600
Comparison
AI-ECG for detection of cardiac amyloidosis
  • Amyloidn = 440
  • Controlsn = 6,600reference
Outcome
AUC of AI-ECG for detection of CA
Methodological detailsvalidation study, 15:1 age- and sex-matched controls
  • Validation study
  • 15:1 age- and sex-matched controls

Performance

As reported in the abstract

AUC, overall cohort

AI-ECG AUC, overall cohort and between amyloid subtypes (95% CI: 0.82-0.86); slight decrease from original study (AUC 0.91)

0.84

Further findings

AUC by race/ethnicity (subgroup)

White, Black and "other" races: similar performance
AUC >0.81
Hispanic patients: decreased performance
AUC 0.66

Performance shift over time

Algorithm performance shift over time not observed

AUC by ECG pattern (subgroup)

Low ECG voltage and infarct pattern
AUC >0.90
LV hypertrophy
AUC 0.75
Left bundle branch block
AUC 0.76

Original publication

Postdevelopment Performance and Validation of the Artificial Intelligence-Enhanced Electrocardiogram for Detection of Cardiac Amyloidosis. JACC Adv. Published 14 September 2023. doi:10.1016/j.jacadv.2023.100612

Composed by AI from the published abstract and checked against it. How Briefs are made →