Authors' conclusion

PS loops analysis in patients undergoing MCS seems to be feasible and may unveil MCS-induced haemodynamic variations.

Study context

Population
Consecutive patients undergoing mechanical circulatory support (MCS) positioning/implantation in a third level cardiological ICU, Siena Hospital, August 2021–November 20219 excluded
Participants
18 patients
Exposure
Haemodynamic profiling by pressure-strain (PS) loops across MCS systems
  • Intra-aortic balloon pump (IABP)n = 3
  • Durable left ventricular assist device (dLVAD)n = 2
  • Impella®n = 2
  • Extracorporeal membrane oxygenation (ECMO)n = 1
  • ECMO and IABPn = 1
Outcome
Non-invasive haemodynamic profiling by pressure-strain (myocardial work) analysis
Methodological detailssingle-centre, consecutive patients
  • Single-centre
  • Consecutive patients

Main finding

As reported in the abstract

Myocardial work / PS loops
  • Myocardial work analysis feasible in each included patient
  • IABP: PS curve shifted rightward and downward; Global work index (GWI) and global wasted work (GWW) decreased, global work efficiency (GWE) increased
  • Continuous-flow pumps (Impella®, dLVAD): PS loop shifted towards a triangular shape
  • ECMO alone: narrower PS loop, decreased GWI and GWE, increased GWW and mean arterial pressure
  • ECMO with IABP: wider PS loop, improved GWI and GWE

Observational data: associations, not effects.