Pulmonary vein narrowing after pulsed field versus thermal ablation

EuropacePublished

  • Secondary analysis of the ADVENT randomised trial
  • multicentre
  • single-blind
  • pre-specified secondary safety endpoint

Authors' conclusion

In this first randomized comparison of PFA vs. thermal ablation, PFA resulted in less PV narrowing-thereby underscoring the qualitatively differential and favourable impact of PFA on PV tissue.

Study context

Population
Drug-refractory paroxysmal atrial fibrillation (AF) undergoing ablation259 pulsed field ablation (PFA), 255 thermal with imaging
Participants
305 vs 302
Comparison
PFA vs thermal ablation
  • PFAn = 305
  • Thermaln = 302reference
Primary endpoint
PV narrowing: change in aggregate PV cross-sectional area (pre-specified, formally tested secondary safety endpoint; superiority by posterior probability > 0.975)
Follow-up
3 months

Primary result

As reported in the abstract

Change in aggregate PV cross-sectional area

PFA

−0.9%

Thermal ablation

−12%

posterior probability > 0.999

Further findings

OutcomeRFCB
Change in aggregate PV cross-sectional area, thermal sub-cohorts · 3 months−19.5%−3.3%
  • Change in aggregate pulmonary vein (PV) cross-sectional area, thermal sub-cohorts: 137 radiofrequency (RF) and 118 cryoballoon (CB)

PV diameters · 3 months

RF PVs decreased, regardless of PV location
80%
Almost half of PFA PV diameters did not decrease

Safety

Significant (≥70%) PV stenosis · 3 months

No subject had significant (≥70%) PV stenosis