Valvular & structural heart disease

Real-Time Biventricular Pressure-Volume Loops During Percutaneous Pulmonary Valve Implantation in Patients With RVOT Dysfunction

Circ Heart FailPublished Mechanistic study

Authors' conclusion

Acute reduction of RV overload by PPVI is accompanied by an instantaneous decline in RV contractility with persistent and inefficient ventriculoarterial coupling. The LV adequately adapts to an increase in pre- and post-load with nonsignificant changes in LV intrinsic function and ventriculoarterial coupling.

Study context

Population
Patients with right ventricular (RV) outflow tract dysfunction (stenosis and pulmonary regurgitation) undergoing percutaneous pulmonary valve implantation (PPVI)
Participants
20 patients
Comparison
Before vs directly after PPVI
Outcome
Acute changes in biventricular intrinsic myocardial function (pressure-volume loops by conductance catheter)
Follow-up
Before and directly after PPVI

Main finding

As reported in the abstract

Load-independent biventricular function, before vs directly after PPVI
RV ventricular elastance, median [IQR], mm Hg/mL per m²: decreased after PPVI
0.26 [0.16-0.83] to 0.19 [0.13-0.42]; P=0.029
Pulmonary arterial elastance, mean±SD, mm Hg/mL per m²: decreased after PPVI
0.32±0.20 to 0.25±0.19; P<0.001
Right ventriculoarterial coupling, mean±SD: no significant change after PPVI
1.14±0.61 to 1.10±0.59; P=0.76
Left ventricular (LV) ventricular elastance, mean±SD, mm Hg/mL per m²: not affected by PPVI
1.31±0.93 to 1.23±0.72; P=0.68
Left ventriculoarterial coupling, median [IQR]: not affected by PPVI
0.75 [0.51-1.23] to 0.82 [0.53-1.10]; P=0.98
Systemic arterial elastance, mean±SD, mm Hg/mL per m²: increased after PPVI
0.83±0.26 to 0.90±0.34; P=0.032
RV compliance: no significant change after PPVI
P=0.37
LV compliance: no significant change after PPVI
P=0.20

Further findings

Relevant pulmonary regurgitation (PR) (≥25%) vs minor PR (<25%) (subgroup)

Lower RV ventricular elastance before PPVI with relevant PR
P = 0.043
Higher LV compliance after PPVI with relevant PR
P = 0.010
Ventriculoarterial coupling similar between the 2 groups
  • n=10 per subgroup

Original publication

Real-Time Biventricular Pressure-Volume Loops During Percutaneous Pulmonary Valve Implantation in Patients With RVOT Dysfunction. Circ Heart Fail. Published 23 December 2025. doi:10.1161/circheartfailure.125.013235

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.