Valvular & structural heart disease

Real-World Outcomes of Fourth-Generation Mitral Transcatheter Repair: 30-Day Results From EXPAND G4

JACC Cardiovasc IntervPublished Prospective postapproval study

Authors' conclusion

This study demonstrates for the first time the effectiveness and safety of MitraClip G4 System at 30 days in a cohort of >1,000 patients with MR in a contemporary, real-world setting.

Study context

Population
Patients with primary (degenerative) or secondary (functional) mitral regurgitation (MR) treated with MitraClip G4, March 2021 to February 2022
Participants
1,141 patients
Outcome
Safety and performance of the MitraClip G4 System in a contemporary real-world setting
Methodological detailsmulticentre, international, single-arm, 60 centres, echocardiography core laboratory
  • Multicentre
  • International
  • Single-arm
  • 60 centres
  • Echocardiography core laboratory

Main finding

As reported in the abstract

30 days
Implantation success
98.0%
Acute procedural success
96.2%
Clips implanted per subject, mean ± SD
1.4 ± 0.6
MR ≤ 2+ at 30 days
98%
MR ≤ 1+ at 30 days (vs baseline P < 0.0001)
91%

Safety

Composite major adverse events and all-cause death · 30 days

Composite major adverse event rate
2.7%
All-cause death rate
1.3%

Original publication

Real-World Outcomes of Fourth-Generation Mitral Transcatheter Repair: 30-Day Results From EXPAND G4. JACC Cardiovasc Interv. Published 26 June 2023. doi:10.1016/j.jcin.2023.05.013

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.