Heart failure & cardiomyopathies

Remote Dielectric Sensing Before and After Discharge in Patients With ADHF: The ReDS-SAFE Heart Failure (HF) Trial

JACC Heart FailPublished Randomised controlled trial

Authors' conclusion

A ReDS-guided strategy to treat congestion improved 1-month prognosis postdischarge in this proof-of-concept study, mainly because of a decrease of the number of HF readmissions.

Study context

Population
Patients hospitalised with acutely decompensated HF
Participants
100 patients
Comparison
Remote dielectric sensing (ReDS)-guided decongestion strategy vs routine care
Primary endpoint
Composite of:
  • Unplanned visits for HF
  • HF rehospitalization
  • Death
Follow-up
1 month after discharge
Methodological detailsinvestigator-initiated, multicentre, single-blind, proof-of-concept
  • Investigator-initiated
  • Multicentre
  • Single-blind
  • Proof-of-concept

Primary result

As reported in the abstract

ReDS-guided vs Routine careHazard ratio (95% CI)P value
Log-rank P = 0.005
0.094(0.012–0.731)
P = 0.003
ReDS-guided
NNT 6 (95% CI 3–17)

Further findings

Median

OutcomeReDS-guidedRoutine careDifference (days)P value
Length of stay862P = 0.203

Original publication

Remote Dielectric Sensing Before and After Discharge in Patients With ADHF: The ReDS-SAFE HF Trial. JACC Heart Fail. Published 28 February 2024. doi:10.1016/j.jchf.2024.01.002

Summarised from the published abstract; every number is checked against it