Heart failure & cardiomyopathies
Remote Dielectric Sensing Before and After Discharge in Patients With ADHF: The ReDS-SAFE Heart Failure (HF) Trial
Authors' conclusion
A ReDS-guided strategy to treat congestion improved 1-month prognosis postdischarge in this proof-of-concept study, mainly because of a decrease of the number of HF readmissions.
Study context
- Population
- Patients hospitalised with acutely decompensated HF
- Participants
- 100 patients
- Comparison
- Remote dielectric sensing (ReDS)-guided decongestion strategy vs routine care
- Primary endpoint
- Composite of:
- Unplanned visits for HF
- HF rehospitalization
- Death
- Follow-up
- 1 month after discharge
Methodological detailsinvestigator-initiated, multicentre, single-blind, proof-of-concept
- Investigator-initiated
- Multicentre
- Single-blind
- Proof-of-concept
Primary result
As reported in the abstract
ReDS-guided vs Routine careHazard ratio (95% CI)P value
Log-rank P = 0.005
0.094(0.012–0.731)
P = 0.003- ReDS-guided
- NNT 6 (95% CI 3–17)
Further findings
Median
| Outcome | ReDS-guided | Routine care | Difference (days) | P value |
|---|---|---|---|---|
| Length of stay | 8 | 6 | 2 | P = 0.203 |
Original publication
Remote Dielectric Sensing Before and After Discharge in Patients With ADHF: The ReDS-SAFE HF Trial. JACC Heart Fail. Published 28 February 2024. doi:10. 1016/ j. jchf. 2024. 01. 002
Summarised from the published abstract; every number is checked against it