Coronary disease & ACS

Safety and efficiency of percutaneous coronary intervention using a standardised optical coherence tomography workflow

EuroInterventionPublished Prospective observational study

Authors' conclusion

The incorporation of a standardised pre- and post-PCI OCT imaging workflow improves procedural efficiency and safety metrics, at a cost of a modestly longer procedure time.

Study context

Population
Percutaneous coronary intervention (PCI) procedures by 45 physicians at 17 US centres over 2 years207 matched procedures
Participants
264 vs 428
Exposure
Optical coherence tomography (OCT)-guided PCI with standardised LL workflow vs angiography-only PCI
  • LL workflown = 264
  • Angion = 428reference
Outcome
Procedural efficiency and safety metrics
Methodological detailsmulticentre, propensity-score matched, 17 US centres
  • Multicentre
  • Propensity-score matched
  • 17 US centres

Main finding

As reported in the abstract

Median procedural time increased with LL workflow (minutes)
9
Vessel preparation time (min): LL workflow 2 vs angio 3
p<0.001
Unplanned additional treatment: LL workflow 4% vs angio 10%
p=0.01
Radiation exposure (mGy): LL workflow 1,133 vs angio 1,269
p=0.02
No difference in contrast utilisation
p=0.28

Observational data: associations, not effects.

Further findings

Device utilisation and treatment strategy

Fewer cineangiography views, predilatation balloons and stents, more direct stenting and greater stent post-dilatation with LL workflow

Original publication

Safety and efficiency of percutaneous coronary intervention using a standardised optical coherence tomography workflow. EuroIntervention. Published 20 February 2023. doi:10.4244/eij-d-22-00512

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.