Valvular & structural heart disease

Self-expanding versus balloon-expandable transcatheter heart valves in patients with excessive aortic valve cusp calcification

Am Heart JPublished prospective-single center registry

Authors' conclusion

In patients with excessive leaflet calcification undergoing TAVR, BEV had a higher risk of annular rupture, but a lower risk of paravalvular regurgitation, and a lower risk of permanent pacemaker implantation compared to SEV. Mortality was comparable between SEV and BEV throughout 5 years of follow-up.

Study context

Population
Patients with severe aortic stenosis and excessive aortic valve cusp calcification (aortic valve complex calcium volume ≥235 mm³) undergoing transcatheter aortic valve replacement (TAVR), August 2007 to June 2023patients with excessive cusp calcification undergoing TAVR, 271 matched pairs
Participants
1,345 patients
Exposure
self-expanding (SEV) and balloon-expandable (BEV) prostheses in patients with excess cusp calcification undergoing TAVR
  • SEVn = 271
  • BEVn = 271
Methodological details1:1 propensity-matched analysis, consecutive patients
  • 1:1 propensity-matched analysis
  • Consecutive patients

Main finding

As reported in the abstract

Procedural success

Procedural success achieved in >85% of patients with no difference between groups

>85%

Observational data: associations, not effects.

Further findings

Transprosthetic gradient

Mild or greater paravalvular regurgitation

  • Transprosthetic gradient: lower with SEV, P < .001
  • Mild or greater paravalvular regurgitation: higher with SEV, P = .008

Mortality · 5 years

No statistically significant difference in mortality between groups (45.1% vs 50.2%)
P = 0.173

Safety

Annular rupture

New permanent pacemaker implantation

  • Annular rupture: more frequent with BEV, P = .030
  • New permanent pacemaker implantation: higher with SEV, P = .001

Original publication

Self-expanding versus balloon-expandable transcatheter heart valves in patients with excessive aortic valve cusp calcification. Am Heart J. Published 18 September 2025. doi:10.1016/j.ahj.2025.09.011

Summarised from the published abstract; every number is checked against it

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.