Cardiometabolic & kidney

Serum Potassium Monitoring Using AI-Enabled Smartwatch Electrocardiograms

JACC Clin ElectrophysiolPublished Diagnostic accuracy study

Authors' conclusion

We validate a deep learning model to predict serum potassium levels from both 12-lead ECGs and single-lead smartwatch data, demonstrating its utility for remote monitoring of hyperkalemia.

Study context

Population
Patients with end-stage renal disease (ESRD); serum potassium paired with electrocardiogram (ECGs) within 1 hour (Cedars Sinai, Stanford Healthcare, Chang Gung Memorial Hospital)training cohort
Participants
152,508 patients
Comparison
AI-ECG (Kardio-Net) prediction of serum potassium from 12-lead, single-lead and smartwatch ECGs
Outcome
Detection of severe hyperkalemia (>6.5 mEq/L) (AUC) and serum potassium prediction (MAE)
Methodological detailsAI-ECG model development and validation, external validation, prospective international smartwatch cohort
  • AI-ECG model development and validation
  • External validation
  • Prospective international smartwatch cohort

Performance

As reported in the abstract

Severe hyperkalemia (>6.5 mEq/L)
Test or modelAUC (primary cohort)Mean absolute error (MAE) (primary cohort)AUC (external Stanford Healthcare (SHC))MAE (external SHC)AUCMAE
12-lead ECG0.852 (95% CI: 0.745-0.956)0.527 mEq/L0.849 (95% CI: 0.823-0.875)0.599 mEq/L
Single-lead ECG0.876 (95% CI: 0.765-0.987)0.575 mEq/L0.807 (95% CI: 0.778-0.835)0.740 mEq/L
Smartwatch ECG0.831 (95% CI: 0.693-0.975)0.580 mEq/L

AUC (primary cohort)

12-lead ECG0.852 (95% CI: 0.745-0.956)
Single-lead ECG0.876 (95% CI: 0.765-0.987)
Smartwatch ECGNot reported in the abstract

Mean absolute error (MAE) (primary cohort)

12-lead ECG0.527 mEq/L
Single-lead ECG0.575 mEq/L
Smartwatch ECGNot reported in the abstract

AUC (external Stanford Healthcare (SHC))

12-lead ECG0.849 (95% CI: 0.823-0.875)
Single-lead ECG0.807 (95% CI: 0.778-0.835)
Smartwatch ECGNot reported in the abstract

MAE (external SHC)

12-lead ECG0.599 mEq/L
Single-lead ECG0.740 mEq/L
Smartwatch ECGNot reported in the abstract

AUC

12-lead ECGNot reported in the abstract
Single-lead ECGNot reported in the abstract
Smartwatch ECG0.831 (95% CI: 0.693-0.975)

MAE

12-lead ECGNot reported in the abstract
Single-lead ECGNot reported in the abstract
Smartwatch ECG0.580 mEq/L

Original publication

Serum Potassium Monitoring Using AI-Enabled Smartwatch Electrocardiograms. JACC Clin Electrophysiol. Published 9 October 2024. doi:10.1016/j.jacep.2024.07.023

Summarised from the published abstract; every number is checked against it

Get them every week

New studies on this topic in My Week and in your Monday e-mail.