Arrhythmias & electrophysiology
Short- and Long-Term Effects of His Bundle Pacing on Myocardial Perfusion, Metabolism, and Function
Authors' conclusion
HISP may be associated with relatively preserved myocardial perfusion, metabolism, and function compared with right ventricular pacing.
Study context
- Population
- Patients admitted for pacemaker implantation, excluding patients with coronary artery disease
- Participants
- 104 patients
- Exposure
- Right ventricular septal pacing (RVSP), HISP and right ventricular apical pacing (RVAP) vs control group
- RVSPn = 44
- HISPn = 17
- RVAPn = 11
- Controln = 32
- Outcome
- Sestamibi and BMIPP %uptake in septal and inferior regions
- Follow-up
- Short- and long-term imaging
Main finding
As reported in the abstract
- RVSP and RVAP groups showed relatively reduced sestamibi and BMIPP %uptake in septal and inferior regions compared with the control group
- No apparent reduction in the HISP group
Observational data: associations, not effects.
Further findings
Left ventricular ejection fraction
- No significant difference among RVSP, HISP, and control groups
- RVAP group showed lower left ventricular ejection fraction
Association of average sestamibi and BMIPP %uptakes in 17 segments with left ventricular ejection fraction
- Significantly associated with left ventricular ejection fraction
Original publication
Short- and Long-Term Effects of His Bundle Pacing on Myocardial Perfusion, Metabolism, and Function. Circ Cardiovasc Imaging. Published 18 November 2026. doi:10. 1161/ circimaging. 126. 019919
Composed by AI from the published abstract and checked against it. How Briefs are made →