Valvular & structural heart disease

Tricuspid Right Ventricular Lead Entrapment in Transcatheter Tricuspid Interventions: The Tri-LEAD Study

JACC Clin ElectrophysiolPublished Retrospective registry study

Authors' conclusion

T-TEER has no detrimental impact on the performance of transvenous RV leads in the short term or midterm.

Study context

Population
Patients who underwent tricuspid transcatheter edge-to-edge repair (T-TEER) with an right ventricular (RV) lead in situ, 2015–2023
Participants
146 patients
Outcome
RV lead dysfunction after T-TEER (change in RV lead function, dislodgement or fracture) and need for intervention due to RV lead dysfunction or cardiac complication
Follow-up
2 years
Methodological detailsmulticentre, international
  • Multicentre
  • International

Main finding

As reported in the abstract

RV lead dysfunction · median follow-up 557 days (Q1-Q3: 278-966 days)

Impedance change >200 Ω

10

6.8%

Threshold change ≥1 V

2

1.4%

RV lead fracture, dislodgement, cardiac structure perforation or pacemaker-related re-interventions

0

T-TEER not associated with increased risk of composite safety endpoint

1.39; 0.64 to 3.02; P = 0.41 (adjusted SHR; 95% CI)

Observational data: associations, not effects.

Further findings

Change in RV lead parameters over time

Sensing
−0.53 mV/year; −1.15 to 0.08; P = 0.094 (95% CI)
Impedance
−2.4 Ω/year; −15.4 to 10.6; P = 0.72 (95% CI)
Threshold
−0.011 V/year; −0.052 to 0.031; P = 0.62 (95% CI)
  • Minimal and not clinically significant

Original publication

Tricuspid Right Ventricular Lead Entrapment in Transcatheter Tricuspid Interventions: The Tri-LEAD Study. JACC Clin Electrophysiol. Published 18 December 2025. doi:10.1016/j.jacep.2025.11.003

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.