Valvular & structural heart disease

Tricuspid inflow E-wave velocity for the assessment of severe or greater tricuspid regurgitation: derivation and external validation of threshold values

Eur Heart J Cardiovasc ImagingPublished derivation and external validation of threshold values

Authors' conclusion

The guideline-recommended threshold of >100 cm/s is highly insensitive for detecting severe or greater TR. Lower cut-offs, particularly 47 cm/s, may be useful for screening to trigger a comprehensive multiparametric assessment.

Study context

Population
Consecutive patients with at least mild tricuspid regurgitation (TR), December 2024 to February 2026patients (77±13 years, 65% women) · 44 (mild TR) · 61 (moderate TR) · 44 (severe TR) · 15 (massive TR) · 14 (torrential TR)
Participants
178 patients
Index test or model
Tricuspid inflow E-wave velocity by pulsed-wave Doppler vs multiparametric echocardiographic grading as the reference standard
Target condition
severe or greater TR
Methodological detailsconsecutive patients
  • Consecutive patients

Performance

As reported in the abstract

Severe or greater TR
StrategySensitivitySpecificityKappa
>100 cm/s threshold5.5%100%0.25
52 cm/s threshold81%67%— not stated in the abstract
47 cm/s threshold90%43%— not stated in the abstract

Sensitivity

>100 cm/s threshold5.5%
52 cm/s threshold81%
47 cm/s threshold90%

Specificity

>100 cm/s threshold100%
52 cm/s threshold67%
47 cm/s threshold43%

Kappa

>100 cm/s threshold0.25
52 cm/s threshold— not stated in the abstract
47 cm/s threshold— not stated in the abstract

— not stated in the abstract

AUC (continuous variable)
0.81

Further findings

External validation

Sensitivity
94%
Specificity
47%

Tricuspid E-wave velocity by TR severity

Mean tricuspid E-wave velocity
56±16 cm/s
Mild TR
47±8 cm/s
Moderate TR
50±10 cm/s
Severe TR
62±16 cm/s
Massive TR
67±13 cm/s
Torrential TR
77±21 cm/s
Patients with E-wave velocity >100 cm/s (one with severe and two with torrential TR)
three

Original publication

Tricuspid inflow E-wave velocity for the assessment of severe or greater tricuspid regurgitation: derivation and external validation of threshold values. Eur Heart J Cardiovasc Imaging. Published 10 November 2026. doi:10.1093/ehjci/jeag304

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.