Coronary disease & ACSDiagnostic or prognostic study

Troponin in early presenters to rule out myocardial infarction

Eur Heart JPublished

  • Diagnostic accuracy study
  • external validation
  • 12 595 (31%) presented within 3 h; 3728 (9%) had MI

Authors' conclusion

In early presenters, a single measurement of high-sensitivity cardiac troponin I below the limit of detection may facilitate the safe rule out of myocardial infarction.

Study context

Population
Consecutive patients with possible MI, by time from symptom onset (≤3, 4–12, >12 h)external validation n = 7088
Participants
41,103 patients
Comparison
2 ng/L vs 5 ng/L vs 99th centile
Outcome
Diagnostic performance (sensitivity, NPV) of a single hs-cTnI measurement for ruling out MI
Follow-up
At presentation

Performance

As reported in the abstract

Rule-out of MI, presenting ≤3 h
Test or modelSensitivityNPV
2 ng/L99.4% (95% CI 99.2%-99.5%)99.7% (99.6%-99.8%)
5 ng/L96.5% (96.2%-96.8%)99.3% (99.1%-99.4%)

Further findings

Sensitivity of 99th centile
71.4% (70.6%-72.2%) · Sensitivity, early presenters · Sensitivity, late presenters 92.5% (92.0%-93.0%)

Rule-out of MI, presenting ≥3 h

Sensitivity and NPV similar for 2 ng/L and 5 ng/L

External validation

Findings consistent in external validation cohort
7088

Original publication

Troponin in early presenters to rule out myocardial infarction. Eur Heart J. Published 23 June 2023. doi:10.1093/eurheartj/ehad376

Summarised from the published abstract; every number is checked against it