Arrhythmias & electrophysiology

Validation of a Demography-Based Adaptive QT Correction Formula Using Pediatric and Adult Datasets Acquired From Humans and Guinea Pigs

Circ Arrhythm ElectrophysiolPublished Validation of a demography-based adaptive QT correction formula

Authors' conclusion

The demography-based QTcAd formula showed superior performance across human and guinea pig age groups, which may enhance the efficacy of rate-corrected K.M.M. for cardiovascular disease diagnosis, risk stratification, and drug safety testing in children and adults.

Study context

Population
Pediatric patients at Children’s National Hospital, subjects from the Pediatric Heart Network database, and guinea pigs across diverse age groupspediatric patients at Children’s National Hospital 1,819 · subjects from the Pediatric Heart Network database 2,400 · in vivo guinea pig ECG recordings N=55 · ex vivo guinea pig ECG recordings N=66
Comparison
QTcAd formula compared to other standard formulae
Outcome
QTc-HR linear regression fit (R ² and slope), 20-year-old human group
Methodological detailsretrospective ECG data, in vivo and ex vivo guinea pig ECG recordings, Langendorff-perfused guinea pig hearts
  • Retrospective ECG data
  • In vivo and ex vivo guinea pig ECG recordings
  • Langendorff-perfused guinea pig hearts

Performance

As reported in the abstract

Test or modelR ²Slope
QTcAd5.1×10 −10−3.5×10 −5
Bazett formula0.210.91

R ²

QTcAd5.1×10 −10
Bazett formula0.21

Slope

QTcAd−3.5×10 −5
Bazett formula0.91

Further findings

OutcomeQTcAdBenatar QTc formula
QTc accuracy, 1-week human263.8±7.3 ms422.5±7.3 ms
Optically measured pseudo-QT interval approximation180.6±17.0 ms— not stated in the abstract

— not stated in the abstract

  • QT correction (QTc) accuracy, 1-week human: QT 263.8±14.8 ms
  • QTc accuracy, 1-week human: QTcAd P =0.62
  • QTc accuracy, 1-week human: Benatar QTc P <0.0001 (overcorrected QTc)
  • Optically measured pseudo-QT interval approximation: Optical pseudo-QT 143±22.5 ms
  • Optically measured pseudo-QT interval approximation: n=44

Optically measured pseudo-QT interval approximation

Better approximated by QTcAd compared with all other formulae

QTcAd vs individual-specific QTc formulae

QTcAd formula was not inferior to individual-specific QTc formulae

Original publication

Validation of a Demography-Based Adaptive QT Correction Formula Using Pediatric and Adult Datasets Acquired From Humans and Guinea Pigs. Circ Arrhythm Electrophysiol. Published 3 February 2025. doi:10.1161/circep.124.013237

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.