Valvular & structural heart disease

Valve Performance Between Latest-Generation Balloon-Expandable and Self-Expandable Transcatheter Heart Valves in a Small Aortic Annulus

JACC Cardiovasc IntervPublished Retrospective cohort study

Authors' conclusion

In TAVR for SAA, SEV demonstrated better hemodynamics than the latest BEV, whereas the latest BEV had lower incidences of PVL ≥ mild and new PMI than the SEV.

Study context

Population
Patients undergoing transcatheter aortic valve replacement (TAVR) for AS with small aortic annulus (annulus area ≤430 mm²)
Participants
1,227 patients
Exposure
Latest-generation balloon-expandable valve (BEV) vs self-expandable valve (SEV) for TAVR in small aortic annulus
  • BEVn = 798
Outcome
Severe prosthesis-patient mismatch, aortic valve mean pressure gradient ≥20 mm Hg, paravalvular leakage (PVL) ≥ mild, new permanent pacemaker implantation and modified VARC-3 device success
Follow-up
Discharge
Methodological detailspropensity score analysis, logistic regression
  • Propensity score analysis
  • Logistic regression

Main finding

As reported in the abstract

  • Modified VARC-3 device success comparable between BEV and SEV
  • Results confirmed by propensity score analysis

Observational data: associations, not effects.

Safety

OutcomeOR (95% CI)
New permanent pacemaker implantation · discharge0.53 (0.33–0.86)

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

Valve Performance Between Latest-Generation Balloon-Expandable and Self-Expandable Transcatheter Heart Valves in a Small Aortic Annulus. JACC Cardiovasc Interv. Published 25 November 2024. doi:10.1016/j.jcin.2024.08.049

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.