Virtual Reality for Preprocedure Planning of Covered Stent Correction of Superior Sinus Venosus Atrial Septal Defects
Authors' conclusion
Heart VR is a rapid and effective tool for predicting suitability for CSC in patients with a superior sinus venosus atrial septal defect and could be a feasible alternative to segmented virtual or physical 3-dimensional models.
Study context
- Population
- Patients with superior sinus venosus atrial septal defect deemed suitable for covered stent correction (CSC) on conventional imaging3 unsuitable at catheterization
- Participants
- 15 patients
- Comparison
- Heart virtual reality (VR) review of preprocedural CT vs findings at catheterization
- Outcome
- Performance of Heart VR to assess patient suitability for CSC
Methodological detailsblinded review, 2 interventionalists
- Blinded review
- 2 interventionalists
Performance
As reported in the abstract
Suitability for CSC
Both interventionalists agreed suitable; all proved technically feasible
n=12
Unsuitable cases: VR uncertain
n=1
Unsuitable cases: interventionalists did not agree on suitability
n=2
Further findings
Strategy for pulmonary vein protection correctly identified
- Interventionalist 1
- 9/12
- Interventionalist 2
- 8/12
- Intraprocedural pulmonary vein protection required, correctly identified with Heart VR
- n=5
- VR predicted pulmonary vein protection needed but not required on balloon interrogation
- 3
VR data loading and review times
- Data loading time
- 82 seconds
- Review time
- 7 minutes