Valvular & structural heart disease

A Novel Echocardiographic Parameter to Confirm Low-Gradient Aortic Stenosis Severity

JACC AdvPublished Diagnostic accuracy study

Authors' conclusion

MG/EOA ratio can be useful in low-flow, LG-AS to confirm AS severity and may complement DSE or aortic valve calcium scoring.

Study context

Population
Patients with low-flow, low-gradient aortic stenosis (AS) (TOPAS study) and an in vitro circulatory modelplus 93 in vitro conditions
Participants
188 patients
Outcome
Diagnostic accuracy of MG/EOA ratio to identify true-severe AS
Methodological detailsretrospective, in vitro and in vivo data sets
  • Retrospective
  • In vitro and in vivo data sets

Performance

As reported in the abstract

Identification of true-severe AS
Test or modelCorrect classification (in vivo)Correct classification (in vitro)
MG/EOA ≥25 mm Hg/cm²85%100%

MG/EOA ≥25 mm Hg/cm²

Correct classification (in vivo)85%
Correct classification (in vitro)100%
Optimal MG/EOA cutoff
≥25 mm Hg/cm²

Further findings

Composite of AV replacement or all-cause mortality · median follow-up 1.41 ± 0.75 years

ComparisonAdjusted HR (95% CI)P value
MG/EOA ≥25 mm Hg/cm²2.36 (1.63–3.42)P < 0.001
Composite of AV replacement or all-cause mortality — Patients meeting composite endpoint
146 (78%)
Composite of AV replacement or all-cause mortality — Harrell's C-index of MG/EOA
0.68
Composite of AV replacement or all-cause mortality — C-index of projected EOA by dobutamine stress echocardiography (DSE)
0.67

Original publication

A Novel Echocardiographic Parameter to Confirm Low-Gradient Aortic Stenosis Severity. JACC Adv. Published 6 September 2024. doi:10.1016/j.jacadv.2024.101245

Summarised from the published abstract; every number is checked against it

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.