Valvular & structural heart disease

The ratio of measured and reference effective orifice areas for discriminating prosthetic aortic valve obstruction

Eur Heart J Cardiovasc ImagingPublished Diagnostic accuracy study

Authors' conclusion

The ratio of measured/reference EOA adds incremental value over conventional Doppler parameters and might be helpful for distinguishing PAV obstruction.

Study context

Population
Mechanical prosthetic aortic valve (PAV) patients with elevated mean transprosthetic pressure gradient (PG) >20 mmHg or peak velocity >3 m/s
Participants
193 patients
Comparison
Measured/reference effective orifice area (EOA) ratio for discriminating mechanical PAV obstruction
  • Obstructionn = 143
Outcome
Discrimination of mechanical PAV obstruction by measured/reference EOA ratio
Methodological detailsretrospective, EOA measured by continuity equation; reference EOA from previous guidelines
  • Retrospective
  • EOA measured by continuity equation; reference EOA from previous guidelines

Performance

As reported in the abstract

Measured/reference EOA ratio

Obstruction

0.63

± 0.18

No obstruction

0.86

± 0.17

P < 0.001

EOA ratio AUC for discriminating PAV obstruction
0.840 (95% CI 0.783-0.898; P < 0.001)
Cutoff 0.71 sensitivity
73.4%
Cutoff 0.71 specificity
82.0%

Further findings

OutcomeAUCP value
Novel algorithm (adding EOA ratio) vs previous guideline algorithmsSimilar accuracy0.763 vs. 0.731P = 0.309
Novel vs previous algorithm in large PAV (≥23 mm) (subgroup)Higher accuracy with novel algorithm0.788 vs. 0.642P = 0.019

Original publication

The ratio of measured and reference effective orifice areas for discriminating prosthetic aortic valve obstruction. Eur Heart J Cardiovasc Imaging. Published 31 October 2022. doi:10.1093/ehjci/jeac206

Summarised from the published abstract; every number is checked against it