Heart failure & cardiomyopathies

Association Between Caseload Volume and Outcomes in Left Ventricular Assist Device Implantations – a EUROMACS Analysis

Eur J Heart FailPublished Retrospective registry cohort study

Authors' conclusion

In patients undergoing LVAD implantation, centre volume was not associated with 1-year survival, but was related to device-related adverse events. Patient profiles differed with respect to centre size.

Study context

Population
Patients undergoing left ventricular assist device (LVAD) implantation, EUROMACS registry, 35 centres, 2011–2020
Participants
4,802 patients35 centres
Exposure
Higher-volume vs lower-volume centres
Outcome
1-year survival
Follow-up
1 year
Methodological detailsmulticentre
  • Multicentre

Main finding

As reported in the abstract

Adjusted 1-year survival
  • No difference in adjusted 1-year survival

Observational data: associations, not effects.

Secondary outcomes

OutcomeAdjusted OR (95% CI)P value
1-year survival, HeartMate 3 devices only (subgroup)0.43 (0.20–0.97)P = 0.041

Adjusted overall survival

Adjusted overall survival probability lower in higher volume centres
P = 0.002
  • Median follow-up 1.54 years (IQR 0.52-3.15)

Cumulative (learning curve) caseload analyses

Similar findings observed

Original publication

Association Between Caseload Volume and Outcomes in Left Ventricular Assist Device Implantations – a EUROMACS Analysis. Eur J Heart Fail. Published 29 August 2024. doi:10.1002/ejhf.3418

Composed by AI from the published abstract and checked against it. How Briefs are made →