Valvular & structural heart disease

Association of Guideline-Concordant Echocardiographic Surveillance With Mortality and Aortic Valve Replacement in US Adults With Aortic Stenosis

Circ Popul Health OutcomesPublished Retrospective cohort

Authors' conclusion

Implementation of the current American College of Cardiology/American Heart Association guideline-recommended echocardiographic surveillance frequency in adults with AS is associated with improved outcomes yet remains suboptimal in real-world settings.

Study context

Population
Patients with aortic stenosis at Kaiser Permanente Northern California, January 1, 2008, to September 30, 2017; patients with prior aortic valve replacement (AVR) excludedpatients with aortic stenosis (AS)
Participants
20,571 patients
Exposure
associations between guideline concordance and all-cause death and receipt of AVR
Methodological detailsvalidated natural language processing algorithms applied to echocardiogram reports, multivariable Cox proportional hazards regression
  • Validated natural language processing algorithms applied to echocardiogram reports
  • Multivariable Cox proportional hazards regression

Main finding

As reported in the abstract

Deaths and AVRs · median follow-up of 5.2 (interquartile range, 3.0-7.4) years
GroupDeathsAVRs
Guideline concordant1929 (28.8%)1783 (26.6%)
Not concordant3683 (42.2%)1266 (14.5%)

Deaths

Guideline concordant1929 (28.8%)
Not concordant3683 (42.2%)

AVRs

Guideline concordant1783 (26.6%)
Not concordant1266 (14.5%)

Observational data: associations, not effects.

Further findings

Adjusted all-cause death, by AS severity

ComparisonaHR
Guideline concordant · moderate AS0.76 (95% CI 0.68–0.85)
Guideline concordant · moderate-to-severe AS0.70 (CI 0.54–0.91)
Guideline concordant · severe AS0.62 (CI 0.51–0.76)

AVR, by AS severity

ComparisonaHR (CI)
Guideline concordant · mild AS2.23 (1.93–2.57)
Guideline concordant · mild-to-moderate AS1.56 (1.22–1.99)
Guideline concordant · moderate AS1.45 (1.28–1.64)
Guideline concordant · moderate-to-severe AS2.09 (1.62–2.69)
Guideline concordant · severe AS1.95 (1.60–2.36)
  • Adjusted all-cause death, by AS severity: lower adjusted all-cause death with guideline concordance for those with at least moderate AS
  • AVR, by AS severity: higher rates of AVR with guideline concordance across all AS severity levels

Rates of guideline concordance

Mild AS
74%
Mild-to-moderate AS
51%
Moderate AS
63%
Moderate-to-severe AS
51%
Severe AS
49%

Factors associated with guideline concordance

Male sex, younger age, having a cardiologist, and certain comorbid conditions were positively associated with guideline concordance

Original publication