Valvular & structural heart disease

Automated Deep Learning Phenotyping of Tricuspid Regurgitation in Echocardiography

JAMA CardiolPublished Diagnostic accuracy study

Authors' conclusion

In this study, an automated pipeline was developed to identify clinically significant TR with excellent performance.

Study context

Population
Color Doppler echocardiogram studies; development at Cedars-Sinai Medical Center (CSMC) 2011–2021 (47,312 studies, 31,708 patients), chosen for parity across tricuspid regurgitation (TR) severity classestest studies per cohort
Participants
2,462 vs 5,549
Comparison
CSMC test vs Stanford Healthcare (SHC)
  • CSMC testn = 2,462
  • SHCn = 5,549
Outcome
AUC, sensitivity and specificity for identifying A4C videos with color Doppler across the tricuspid valve, and AUC for identifying moderate to severe or severe TR
Methodological detailstemporally distinct test set, geographically distinct external cohort
  • Temporally distinct test set
  • Geographically distinct external cohort

Performance

As reported in the abstract

Test or modelView classifier AUCStudies with ≥1 A4C color Doppler video identifiedView classifier sensitivityView classifier specificityModerate or severe TR AUCSevere TR AUCStudies with ≥1 TR color Doppler video identified
CSMC test1.000 (95% CI, 0.999-1.000)2410 of 24620.975 (95% CI, 0.968-0.982)1.000 (95% CI, 1.000-1.000)0.928 (95% CI, 0.913-0.943)0.956 (95% CI, 0.940-0.969)
SHC0.999 (95% CI, 0.998-0.999)0.949 (95% CI, 0.944-0.955)0.999 (95% CI, 0.999-0.999)0.951 (95% CI, 0.938-0.962)0.980 (95% CI, 0.966-0.988)5268 of the 5549

View classifier AUC

CSMC test1.000 (95% CI, 0.999-1.000)
SHC0.999 (95% CI, 0.998-0.999)

Studies with ≥1 A4C color Doppler video identified

CSMC test2410 of 2462
SHCNot reported in the abstract

View classifier sensitivity

CSMC test0.975 (95% CI, 0.968-0.982)
SHC0.949 (95% CI, 0.944-0.955)

View classifier specificity

CSMC test1.000 (95% CI, 1.000-1.000)
SHC0.999 (95% CI, 0.999-0.999)

Moderate or severe TR AUC

CSMC test0.928 (95% CI, 0.913-0.943)
SHC0.951 (95% CI, 0.938-0.962)

Severe TR AUC

CSMC test0.956 (95% CI, 0.940-0.969)
SHC0.980 (95% CI, 0.966-0.988)

Studies with ≥1 TR color Doppler video identified

CSMC testNot reported in the abstract
SHC5268 of the 5549