Valvular & structural heart diseaseDiagnostic or prognostic study

High-Throughput Deep Learning Detection of Mitral Regurgitation

CirculationPublished

  • Diagnostic accuracy study
  • internal and external validation
  • multicentre

Authors' conclusion

In this study, a novel automated pipeline for identifying clinically significant MR from full transthoracic echocardiography studies demonstrated excellent performance across large numbers of studies and across multiple institutions.

Study context

Population
Transthoracic echocardiograms from Cedars-Sinai Medical Center (development, internal test) and Stanford Healthcare (external test)echocardiograms (2,587,538 videos)
Participants
58,614 echocardiograms
Comparison
Automated deep learning pipeline for detection of clinically significant mitral regurgitation (MR) on transthoracic echocardiograms
  • Cedars-Sinai test setn = 1,800
  • Stanford Healthcare testn = 915
Outcome
Detection of clinically significant (moderate or severe) MR

Performance

As reported in the abstract

Detection of MR moderate or greater and severe MR
Test or modelAUC, MR moderate or greaterAUC, severe MR
Cedars-Sinai Medical Center test cohort0.916 (0.899-0.932)0.934 (0.913-0.953)
Stanford Healthcare test cohort0.951 (0.924-0.973)0.969 (0.946-0.987)

Further findings

OutcomeCedars-Sinai test setStanford Healthcare test
View classifier: identification of apical 4-chamber color Doppler videos across the mitral valve · vs manually curated videos
AUC0.998 (0.998-0.999)Not reported in the abstract
Correctly identified3452 of 35391051 of 1055
Sensitivity0.975 [0.968-0.982]0.996 [0.990-1.000]
Specificity0.999 [0.999-0.999]0.999 [0.999-0.999]

Original publication

High-Throughput Deep Learning Detection of Mitral Regurgitation. Circulation. Published 12 August 2024. doi:10.1161/circulationaha.124.069047

Summarised from the published abstract; every number is checked against it