Characterization of Screen Failures Among Patients Evaluated for Transcatheter Tricuspid Valve Repair (TriSelect-Study)
Authors' conclusion
The majority of TTVr screen failure patients are excluded due to TV, right atrial, and RV enlargement. However, a significant proportion is excluded due to clinical futility.
Study context
- Population
- Patients evaluated for transcatheter tricuspid valve repair (TTVr) for tricuspid regurgitation (TR) at 3 centres in the US and Germany, January 2016 to December 2021
- Participants
- 547 patients3 centres
- Outcome
- Screen failure for TTVr: clinical characteristics and cardiac morphology
Methodological detailsmulticentre
- Multicentre
Main finding
As reported in the abstract
- Accepted for TTVr
- 58.1%
- Deemed unsuitable for TTVr
- 41.9%
- Exclusion reason among unsuitable: anatomical criteria
- 56.8%
- Exclusion reason: clinical futility
- 17.9%
- Exclusion reason: low symptom burden
- 12.7%
- Exclusion reason: technical limitations
- 12.7%
Key notes
- Independent screen failure predictors (regression): Right ventricular (RV) and right atrial size, TV coaptation gap, tethering area
Further findings
Management of excluded patients
- Conservative medical therapy
- 71.6%
- Tricuspid valve (TV) surgery
- 22.3%
- Later eligible for transcatheter TV replacement in US clinical trials
- 6.1%
Baseline characteristics
- Median age, years (IQR 74-83)
- 80
- Female
- 60.0%
Original publication
Characterization of Screen Failures Among Patients Evaluated for Transcatheter Tricuspid Valve Repair (TriSelect-Study). JACC Cardiovasc Interv. Published 10 July 2023. doi:10. 1016/ j. jcin. 2023. 03. 036
Composed by AI from the published abstract and checked against it. How Briefs are made →