Coronary disease & ACS

Durable-polymer versus biodegradable-polymer drug-eluting stents in acute coronary syndromes: three-year outcomes of the HOST REDUCE POLYTECH RCT Trial

EuroInterventionPublished Randomised controlled trial

Primary result · POCOResult — go to the resultHazard ratio 0.96 95% CI 0.80–1.14

Authors' conclusion

In ACS patients, DP-DES showed similar results to BP-DES regarding the POCO up to 3 years. For the DOCO, DP-DES were superior to BP-DES; this was due to the higher event rate during the period of polymer degradation.

Study context

Population
Patients with acute coronary syndrome (ACS)
Participants
3,413 patients
Comparison
Durable-polymer DES (DP-DES) vs biodegradable-polymer DES (BP-DES)
  • DP-DESn = 1,713
  • BP-DESn = 1,700reference
Primary endpoint
Patient-oriented composite outcome (POCO)
Follow-up
Up to 3 years

Primary result

POCO · 3-year follow-up

Hazard ratio

0.96

95% CI 0.80–1.14

P = 0.613

By group

DP-DESvs BP-DES
HR 0.96 (95% CI 0.80–1.14); P = 0.613

As reported in the abstract

Secondary outcomes

OutcomeDP-DESBP-DESHR (95% CI)P value
Device-oriented composite outcome (DOCO), key secondary · 3-year follow-up6.0%8.0%0.73 (0.57–0.95)P = 0.020
DOCO, landmark analysis · 8 to 16 months post-PCI1.8%3.3%0.54 (0.34–0.84)P = 0.007
  • Device-oriented composite outcome (DOCO), landmark analysis: mainly driven by reduction of target lesion revascularisation

Original publication

Durable-polymer versus biodegradable-polymer drug-eluting stents in acute coronary syndromes: three-year outcomes of the HOST REDUCE POLYTECH RCT Trial. EuroIntervention. Published 17 June 2024. doi:10.4244/eij-d-23-01053