Heart failure & cardiomyopathies

Dynamic Risk Assessment of Severe Ventricular Arrhythmia in Patients With Implantable Defibrillators and Reduced Left Ventricular Ejection Fraction

Circ Arrhythm ElectrophysiolPublished develop and validate a predictive model based on dynamic changes in intracardiac electrograms

Authors' conclusion

A convolutional neural network-derived model, grounded in the pathophysiology of HFrEF, provides dynamic risk assessment of VF or polymorphic ventricular tachycardia events in patients with implantable cardioverter-defibrillator devices.

Study context

Population
Patients with implantable cardioverter-defibrillators and heart failure with reduced ejection fraction (HFrEF)2 independent cohorts of patients with ICDs · 5,089 (First cohort, training and internal validation, 50 centers, 199 218 tracings) · 2,040 (External validation cohort, 7 centers, 369 845 tracings)
Predictors
Convolutional neural network-derived model analyzing temporal patterns of R-wave amplitude, QRS duration, and premature ventricular complex burden
Predicted outcome
first VF or polymorphic ventricular tachycardia events
Methodological detailsexperimental studies in pigs, 2 independent cohorts, external validation
  • Experimental studies in pigs
  • 2 independent cohorts
  • External validation

Model performance

As reported in the abstract

AUROC
Training cohort (CNN model)
0.787(0.753-0.817)
External validation cohort (CNN model)
0.725(0.709-0.739)

Further findings

Inducible VF episodes in pigs (HFrEF decompensation vs sham-operated controls)

  • Inducible ventricular fibrillation (VF) episodes in pigs (HFrEF decompensation vs sham-operated controls): P <0.001

Static risk assessment based on clinical variables

AUROC, static clinical-variable risk assessment
0.617 [0.602-0.632]
Dynamic CNN model significantly outperformed static risk assessment

Inducible VF episodes in pigs (HFrEF decompensation vs sham-operated controls)

HFrEF decompensation associated with QRS prolongation and reduced bipolar R-wave amplitude

Original publication

Dynamic Risk Assessment of Severe Ventricular Arrhythmia in Patients With Implantable Defibrillators and Reduced Left Ventricular Ejection Fraction. Circ Arrhythm Electrophysiol. Published 20 November 2026. doi:10.1161/circep.125.015093

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.