Valvular & structural heart disease

Echocardiographic estimation of pulmonary pressure in patients with severe tricuspid regurgitation

HeartPublished Diagnostic accuracy study

Authors' conclusion

The reliability of the estimation of sPAP in patients with severe TR could be altered by high RAP which cannot be estimated with current thresholds.

Study context

Population
Consecutive patients with right heart catheterisation and TTE within 48 hours, University Hospital of Rennes78 with severe tricuspid regurgitation (TR)
Participants
236 patients
Comparison
TTE vs right heart catheterisation for systolic pulmonary artery pressure (sPAP)
Outcome
Reliability of sPAP assessment by TTE (Lin's concordance coefficient, Bland-Altman analysis)
Methodological detailssingle-centre, consecutive patients
  • Single-centre
  • Consecutive patients

Performance

As reported in the abstract

Concordance of TTE vs catheterisation sPAP

Lin's concordance coefficient (LCC), total population (95% limits of agreement (LOA) 0.74, 0.84)

0.80

LCC, severe TR (95% LOA 0.49, 0.80), propensity to underestimation by TTE

0.67

Further findings

Independent predictor of sPAP misestimation by TTE: 'V-wave cut-off' sign on continuous-wave Doppler

OR (95% CI)P value
'V-wave cut-off' signFound exclusively in severe TR3.74 (1.48–9.30)P < 0.01

sPAP underestimation by TTE with elevated right atrial pressure (RAP)

Underestimation by TTE of about 8 mmHg

Original publication

Echocardiographic estimation of pulmonary pressure in patients with severe tricuspid regurgitation. Heart. Published 12 October 2023. doi:10.1136/heartjnl-2023-322893

Composed by AI from the published abstract and checked against it. How Briefs are made →