Evaluation of deep learning estimation of whole heart anatomy from automated cardiovascular magnetic resonance short- and long-axis analyses in UK Biobank

Eur Heart J Cardiovasc ImagingPublished Cross-sectional study

Authors' conclusion

Neural network reconstructions of whole heart volumes had significantly stronger associations with CVD and risk factors than standard volume estimation methods in an automatic processing pipeline.

Study context

Population
UK Biobank individuals with cardiovascular disease (CVD) and without CVD4,723 with CVD, 5733 without · UK Biobank individuals with CVD 4,723 · without CVD 5,733
Exposure
Deep learning 3D whole heart volumes vs standard cardiovascular magnetic resonance (CMR) volume estimation
Outcome
Strength of association of end-diastole (ED) and end-systole (ES) chamber volumes with CV risk factors and disease (R2, P-values, AUC)
Methodological detailsUK Biobank, fully automated machine learning pipeline
  • UK Biobank
  • Fully automated machine learning pipeline

Main finding

As reported in the abstract

  • Univariate and multivariate associations with most risk and disease factors stronger for deep learning volumes (higher R2, more significant P-values), particularly for sex, age and BMI
  • Deep learning volumes vs Standard volumes: P < 0.001

Observational data: associations, not effects.

Original publication

Evaluation of deep learning estimation of whole heart anatomy from automated cardiovascular magnetic resonance short- and long-axis analyses in UK Biobank. Eur Heart J Cardiovasc Imaging. Published 9 May 2024. doi:10.1093/ehjci/jeae123

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.