Valvular & structural heart disease

Feature-tracking computed tomography left atrial strain and long-term survival after transcatheter aortic valve implantation

Eur Heart J Cardiovasc ImagingPublished Cohort study

Authors' conclusion

PALS assessed with FT MDCT is independently associated with all-cause mortality after TAVI.

Study context

Population
Patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI) with pre-TAVI multi-detector computed tomography (MDCT) suitable for feature-tracking (FT) left atrial (LA) strain assessment
Participants
376 patients
Exposure
PALS quartiles and all-cause mortality after TAVI
Outcome
All-cause mortality
Follow-up
Median 45 (22-68) months

Main finding

As reported in the abstract

median 45 (22-68) months
Hazard ratio (95% CI)P value
PALSmultivariable Cox regression
1.044(1.012–1.076)
P = 0.006
Q3vs Q1
2.262(1.335–3.832)
P = 0.002
Q4vs Q1
3.116(1.864–5.210)
P < 0.001
Deaths during follow-up
148 (39%)

Observational data: associations, not effects.

Original publication

Feature-tracking computed tomography left atrial strain and long-term survival after transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging. Published 12 August 2022. doi:10.1093/ehjci/jeac157