Valvular & structural heart disease

Four-year durability of the Myval balloon-expandable transcatheter aortic valve

EuroInterventionPublished multicentre ambispective study

Authors' conclusion

In a real-world cohort, 4-year outcomes with the balloon-expandable Myval series demonstrated acceptable valve durability, low haemodynamic deterioration, and comparable performance to contemporary TAVI systems.

Study context

Population
Patients with severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI) with the Myval series between December 2017 and April 2020from 9 institutions, all completed 4-year follow-up or were followed up until death
Participants
366 patients
Outcome
Survival
Follow-up
4 years

Main finding

As reported in the abstract

4-year survival rate

81.8%

Further findings

Residual ≥moderate aortic regurgitation

Residual ≥moderate aortic regurgitation
9.2%

Bioprosthetic valve failure (BVF) (VARC-3)

BVF criterion 1 (symptomatic valve failure)
3.3%
No cases of BVF criteria 2 or 3

Haemodynamic valve deterioration (HVD) (VARC-3) · 4 years

Stage 2 HVD
9.7%
Stage 3 HVD
0.7%

Patient-prosthesis mismatch (PPM) (VARC-3) · 1 year

Moderate PPM
3.6%
Severe PPM
2.1%

Original publication

Four-year durability of the Myval balloon-expandable transcatheter aortic valve. EuroIntervention. Published 7 July 2025. doi:10.4244/eij-d-24-01112