Arrhythmias & electrophysiology

Hemolysis Related to Pulsed-field Ablation (PFA): Comparative Study of Next-Generation Nanosecond With Conventional PFA Systems

JACC Clin ElectrophysiolPublished prospective analysis

Authors' conclusion

Hemolysis commonly occurs across PFA procedures, irrespective of pulse duration, and is greater with single-shot than focal systems.

Study context

Population
Consecutive patients with atrial fibrillation undergoing first-time PFA67% male, mean age 58.9 ± 11.68
Participants
94 patients
Exposure
Hemolysis profiles across different PFA systems
  • Nano PFA 360n = 30
  • Pentasplinen = 34
  • Lattice tipn = 30
Outcome
Hemolysis (>10 mg/dL decrease in Hp between T1 and T2)
Follow-up
24 hours after the procedure
Methodological detailsconsecutive patients
  • Consecutive patients

Main finding

As reported in the abstract

Hemolysis occurred, all patients

88

93.6%

Observational data: associations, not effects.

Further findings

Significant hemolysis (Hp ≤ 25 mg/dL) · 24 hours after the procedure

  • Significant hemolysis (haptoglobin (Hp) ≤ 25 mg/dL): P < 0.001

Significant hemolysis, multivariable analysis

Nano PFA 360 and Pentaspline associated with a similarly high risk of significant hemolysis compared with Lattice tip
P < 0.001
No statistically significant difference between Nano PFA 360 and Pentaspline catheters

Baseline and procedural characteristics

No statistically significant differences among the 3 systems

Original publication

Hemolysis Related to PFA: Comparative Study of Next-Generation Nanosecond With Conventional PFA Systems. JACC Clin Electrophysiol. Published 22 July 2026. doi:10.1016/j.jacep.2026.06.022

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.